Migration of UC VMs that are live and processing live traffic is supported, but note that Cisco testing cannot cover every possible operational scenario.
VMware Update Manager (VUM)
But deploying with sum of vcpu = sum of Logical Processors in ESXi or sum of vcpu(sum of physical CPU cores) is not supported unless specifically indicated by an application. Cisco TAC does not engage on issues isolated to 3rd-party-provided/supported hardware or 3rd-party-provided/supported software. OVAs for ESXi 5.x include vmv7 and vmv8). Before reading the best practices below, verify support at Supported Editions and Features of VMware vSphere ESXi, VMware vCenter and VMware vSphere Client. In ESXi 5.1+ vMotion allows "DAS to DAS", i.e. ESXi 4.0, 4.1, 5.0, 5.1, 5.5). CUCM sending CDR/CMR to the external billing server does not incur any additional IOPS. In QuoteCollab tool, model VM placement and note tallied hardware requirements for each hardware node. For VM configurations supporting more than 1,000 users, plan for 160 IOPS during steady-state.
Cisco Collaboration apps only require vmv4 functionality, so a newer vmv is usually transparent. Required usable space is ~954GB. a "cold migration" or "host to host migration", is not vMotion and is supported. Start learning cybersecurity with CBT Nuggets. Physical examples (non-exhaustive) include Cisco route/switch/fabric products like Catalyst, ISR, ASR, ASA, Nexus, UCS Fabric Interconnects/Extenders, ACI, SDA, SD WAN. Another alternative is manual Virtual Machine shutdown and migration. Does not apply to ESXi version upgrades. Plan for a B200 M5 blade that emulates the specs of Business Edition 6000M (M5) appliance. Use of Cisco Nexus 1000V is therefore strongly recommended as this is currently the only way to deterministically manage traffic congestion through the UCS 6x00. If what you are looking for isn't listed, search Cisco.com Support or post in the Cisco Community. Follow Business Edition 6000 ordering guide for quoting instructions (toplevel product ID BE6M-M5-K9). SIP trunks.
C220 M5 SFF, C240 M5 SFF, HX220c M5, B200 M5, etc.). Assume WAN between sites already exists and satisfies applications clustering over WAN requirements. Minimum required memory is 30GB. 3
Cisco Collaboration apps only require vmv4 functionality, so a newer vmv is usually transparent. Unified CCE
Storage vMotion
Elements may be Cisco or 3rd-party, physical or virtual. See best practices for Multiple Physical NICs and vNICs. The snapshots must be merged before the Cisco Unified CCE and CVP systems transition to production. Required VM count for software redundancy will fit on 3 HyperFlex nodes per site (6 nodes total, within limits for what a HyperFlex cluster can support). Not supported.
For more information, see http://blogs.cisco.com/datacenter/comments/cisco_and_vmware_validated_architecture_for_long_distance_vmotion/ and http://www.cisco.com/en/US/solutions/collateral/ns340/ns517/ns224/ns836/white_paper_c11-557822.pdf. One Unity Connection 1000 user VM (2vcpu) used for EITHER Single Inbox or IMAP. Like the BE7000H (M5), we will also spec dual quad-port 1GbE NICs to provide extra links and accommodate typical needs for NIC teaming and/or VLAN trunking.
See also VMware Data Recovery and Copy Virtual Machine.
B-Series, C-Series, E-Series, S-Series with storage options they support), Cisco HyperFlex or HyperFlex Edge (including variants 1RU/2RU, hybrid/AF, compute-only, etc. Before reading the best practices below, verify support at Supported Editions and Features of VMware vSphere ESXi, VMware vCenter and VMware vSphere Client. ), SAN/NAS shared storage: adapter for storage access, the transport network (FC, iSCSI, NFS, etc.) * Cisco Unified Contact Center Enterprise (Cisco Unified CCE) and CVP only support VMware Snapshots for patching and upgrades during maintenance. This is because during the vMotion cutover, the system is paused, which for real-time UC apps creates service interruption which degrade voice quality after the migration for calls in progress. Cisco recommends to power off the VMs before the SAN replication occurs.
Cisco recommendation is to use the latest Maintenance release supported by the hardware vendor. Plan for a B200 M5 blade that emulates the specs of Business Edition 7000M (M5) appliance. Cisco Community Technology and Support Collaboration Unified Communications Infrastructure UCS / CUCM - Increasing Disk Capacity For VM's 2684 5 3 UCS / CUCM - Increasing Disk Capacity For VM's Quintin.Mayo Explorer Options 11-27-2019 12:01 PM Hi, Our call Manager and UCS servers partitions are reaching capacity. Click Add Trunk to create a new SIP trunk. Any changes to a VM must align with the best practices in. See also VMware Data Recovery and Copy Virtual Machine. See VMware vCenter Converter for what is supported. For latency/performance, rule of thumb would be 14 disks (1 HDD per physical CPU cores).
For isolation of "complex" issues, if there is no evidence the application is the problem and/or the application logs point to VMware/hardware layer, then the application is ruled out and the problem will be deemed isolated to VMware/hardware layer. Step 5 After installation of the new version of VMware Tools is complete, remove the VMware Tools tar file from the virtual CD/DVD drive. Before reading the best practices below, verify support at Supported Editions and Features of VMware vSphere ESXi, VMware vCenter and VMware vSphere Client. VDP in vSphere ESXi 5.1 replaces "VDR" (vSphere Data Recovery / VMware Data Recovery) in prior ESXi releases: see http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=2016565. BE7000M (M5) appliance uses Intel Xeon 6132 CPU (14C/2.6GHz). Which VMs are active, and how many are active simultaneously, depends on how the CUCM cluster nodes are setup with respect to service activation, redundancy groups, etc. 5600 / 2.66 GHz vs. E7v1 / 2.40 GHz). If the server is Cisco UCS, you may need to use a UCS-specific image for U3 on vmware.com. Setting up software at a staging location to be later moved or deployed elsewhere. Before reading the best practices below, verify support at Supported Editions and Features of VMware vSphere ESXi, VMware vCenter and VMware vSphere Client. HCL, latencies, application VM capacity and performance needs). A redundant power supply may be selected. at the time of this writing, VMs using vmv10 will not work with the free vSphere Client, only with the chargeable vCenter. is not supported (similar to moving from a more powerful server to a less powerful server, such as MCS 7845 ? 5.1 U1) if required by its guest OS or for hardware compatibility. VMware Tools are specialized drivers for virtual hardware that is installed in the UC applications when they are running virtualized. . However, using this feature to patch and update the guest OS is only supported by some applications and some versions, this is what is shown on this page when referring to VUM support. Trace collection is 100 IOPS (occurs on all VMs for which tracing is enabled). VMware "Long Distance vMotion" (site to site) is not supported. Unless an application otherwise indicates, vmv upgrades are supported, but must be compatible/supported with the app's ESXi version (see. This page has been updated to reflect compatibility with the latest M5 hardware.
VMware Boot from SAN
Not supported. See vMotion for what is supported.Long Distance vMotion is a joint Cisco and VMware validated architecture for using the vMotion feature across data centers. vSphere Storage Appliance (VSA)
If VSA is desired to be used as shared storage for a virtualized Cisco Collaboration deployment, it must meet the storage requirements for UC on UCS Specs-based or 3rd-party Server Specs-based (e.g. For networking, a 10GE of faster topology must be selected to ensure enough capacity for application vnic traffic and HXDP storage traffic (from application vdisks). 5.1 U1) if required by its guest OS or for hardware compatibility. Follow HX DIMM population rules for 8x16GB=128GB. Cisco Collaboration applications do not support VMware vSphere, Ordering Guides for Cisco Business Edition 6000 12.5+ and Cisco Business Edition 7000 12.5+ at, Cisco Business Edition 6000 12.5+ Installation Guides at, Cisco Business Edition 7000 12.5+ Installation Guides at. Before reading the best practices below, verify support at Supported Editions and Features of VMware vSphere ESXi, VMware vCenter and VMware vSphere Client.
Cisco recommends to power off the VMs before the SAN replication occurs. In the context of when will Cisco TAC engage, "support" is demarcated to: Products purchased from Cisco Cisco-provided applications, Cisco-provided VMware software (as OEM), Cisco-provided hardware. A Cisco HyperFlex Data Platform Edge Edition 1 Yr Subscription is required for each node in the cluster. See VMware Consolidated Backup for what is supported. Cisco MediaSense
Moving a shut down VM during a maintenance window, i.e. If uploading a VM copy as a "whole system restore", clustered UC applications such as CUCM will probably require their replication to be manually "fixed" via a CLI command. 3rd-Party Physical To Virtual (P2V) Migration Tools
Otherwise, Cisco Collaborations apps do not prescribe/proscribe how the hardware is managed. This setting usually needs to be disabled on an ESXi host running Collaboration app VMs (either new install of ESXi 4.1+, or upgrade from ESXi 4.0 to 4.1+ followed by upgrading VMwareTools in app VMs to 4.1+).
Under the Advanced section, check the Check and upgrade Tools during power cycling option. Slower CPUs maybe possible, but will only have caveated support. Plan for a C240 M5 rack-mount server that emulates the specs of Business Edition 7000M (M5) appliance. 1K phones per VM
Cisco only provides Application OVAs using an older version of VMware-native vmtools, that customers may update if needed for compatibility with their environment. E.g. Before I purchase the CUCM 11.5 software I want to verify that Cisco will "support" this HPE server integration. For all other changes, it is recommended to backup the application, reinstall application on a new OVA file, and restore the application. If you choose to use access options like VLAN trunking or link aggregation, multiple physical links may be required. Virtual Appliance Packaging of UC apps
VMware Cloud on Dell EMC VxRail, Amazon AWS Outposts, Microsoft Azure Stack, GKE On-prem and others are not supported). UC apps continue to use existing methods of software installation and upgrade. Also always ensure a DRS backup of the Cisco Collaboration applications is available in case there are issues with the replicated VMs. The RAID controller (whether motherboard, PCIe, etc.) Plan for dual RAID5 volumes. Regardless of processor base frequency, Xeon 5200/5100, 4200/4100, E5-2400 are not supported for deployments >1000 users or >2500 devices unless specifically indicated. See the documentation for the UC application software or UC appliance software to see what is supported. Cisco physical / virtual networking infrastructure is presumed transparent to Collaboration workloads. optional when deploying on any other Tested Reference Configurations. E.g. vSphere Storage Appliance (VSA)
VMware Fault Tolerance
Was only sold as 5.x. Latency values over time are expected to fluctuate. BE7000M (M5) appliance uses Intel Xeon 6132 CPU (14C/2.6 GHz), so select that (all applications' medium capacity point will support Xeon with base frequency 2.60 GHz). moving VM from ESXi host A to ESXi host B in another chassis, closet, building, etc. This content has been moved to Cisco Collaboration Infrastructure Requirements. 2 or 3
With version 8.x of Cisco's Communications Manager (CallManager or CUCM) software, the capability to virtualize the OS in VMware is the most touted feature. When enabled on VMs running ESXi 4.1 or later, you may experience slow TCP performance on certain operating systems (depending on which Collaboration application and version). Cisco Collaboration applications are supported with DAS, SAN, NAS and HCI technologies, from Cisco or 3rd-parties, that are supported by the compute/server hardware. It is handled as part of the guest OS in the Cisco application workload. Cisco Collaboration apps do not prescribe or proscribe individual ESXi patches and updates. Used to preserve the state of a VM without copying or creating additional VMs, effectively as a backup/restore or reversion technique. Updates are performed automatically. When deployed on other supported servers, use for publishers, subscribers, standalone TFTP, standalone multicast MOH nodes, ELM or PAWS-M. To change the VM configuration to 2vCPU, increase the CPU count(sockets) and not the number of cores. I have nearly a decade of experience designing, installing, and troubleshooting Cisco Unified Communications systems of all sizes. "Rogger"). Other features from vSphere Standard Edition. Some virtualized UCS servers are configured with multiple physical NICs (see UCS page at http://www.cisco.com/go/swonly). Below are some guidelines for Cisco UCS C-Series servers with HDD DAS. For example, initial deployment of the OVA and UC application may have been done on ESXi 4.0 update 1. Requires SAN storage. VMware Dynamic Power Management
E.g. A check will now be performed each time the VM powers on to determine if the tools need to be updated. Go back to: Cisco Collaboration Virtualization. "DAVG/cmd" (Device Average Latency per command) - an indicator of disk subsystem performance.
With a particular supported major/minor version (such as ESXi 5.1)
Make sure to identify customer's access network switching/fabric infrastructure and copper vs. fiber cabling before you buy compute/storage hardware, so you procure the right interface cards/ports/cables. Two HX Edge nodes are sufficient to provide hardware redundancy. CUCM Class of Service. Call Cisco technical support only.For optimal routing to best support team, recommend open service request with keyword "Business Edition", not "VMware". Prior to copying, the VM must first be shutdown (which will shut down the virtual server, the UC OS and the UC application).
via Distributed Resource Scheduler [DRS]), a few applications have caveated support (see here for details); otherwise it is not supported. For details on general-purpose vCenter licenses, see the following: Cisco UCS Spec Sheet or Cisco HyperFlex Spec Sheet for the hardware model of interest (e.g. 9.0
If the UC app is listed as "Supported with Caveats", then support is as described below:
Co-resident application VMs are restricted: One Prime Collaboration Provisioning Small VM, One Unity Connection 1000 user VM (1vcpu). 3rd-Party Physical To Virtual (P2V) Migration Tools. Note that Cisco Unified Communications applications upgrades, patches and updates can not be delivered through VMware Update Manager. Expected to be 0ms in an ideal environment. Example uses VIC 1440 mLOM. The following links can be used to determine if an individual Maintenance Release or patch "can" or "should" be deployed: VMware Compatibilty Guide (http://www.vmware.com/go/hcl) for the the vSphere ESXi Major/Minor version supported by Cisco Collaboration. The system reboots twice. The following are not recommended as tend to be too slow: SATA disks, SAS disks with <10kbps. Obtain new version key from My Cisco Entitlements (MCE).Obtain installation media from vmware.com (Cisco UCS-specific images). See the Business Edition 6000/7000 documentation for more details. Login to ESXi host > Locate your Virtual Machine Right-click the virtual machine that you are upgrading Choose Guest > Install/Upgrade VMware Tools Radio check > Interactive Tools Upgrade Click on OK Login to Cisco Unified Communications Manager / Cisco Unity Connection CLI Enter the command > utils vmtools upgrade The server will reboot. Existing UC app methods of backing up the software continue to be supported.
If vMotion is suspected as the cause of dropped calls, customers should gather appropriate application logs as well as performance data from VMware vCenter and send to Cisco TAC for analysis. If you use vCenter, then unless otherwise indicated, Cisco applications do not require their own dedicated vCenter.
See the documentation for the UC application software or UC appliance software to see what is supported. This feature effectively provides a method to do full system backup/restore, take system images or revert changes to software versions, user data and configuration changes. Remember each HyperFlex cluster node runs an HXDP Controller VM. NOTE: support varies by app and version. VMsafe
Not supported for other applications. Virtual Appliance Packaging of UC apps
if you have more than 10,000 users in Cisco Unified Communications Manager, you must use the 5,000 user OVA template at a minimum, even if you plan to license less than 5,000 users of IM and Presence. Certain other virtualization features may mandate vCenter based on VMwares license editions. vSphere Data Protection (VDP)
See VMware Consolidated Backup for what is supported. To date this has never been the case, so if the hardware vendor supports it, it is allowed even if unlisted. The vmv represents the version of virtual hardware. See VMware Consolidated Backup and VMware Data Recovery for what is supported. Use the following procedure to perform this upgrade. It can be used to supplement software redundancy as a means of fast, automated Failed-server recovery when a VM (but not the application) is hung or if there is a fault with the physical host server or VMware software. Each HyperFlex node will require a HyperFlex Data Platform (HXDP) storage controller VM of 8vcpu, in addition to the application VMs. No version downgrades. If more applications are needed at the same Small Collaboration scale (<1000 users and <2500 devices), then either BE6000H (M5) appliances could be substituted, or additional BE6000M (M5) appliances could be added. Not supported. For deployments leveraging NAS/SAN storage and FCoE (such as UC on UCS B-Series / C-Series connected to Cisco 6x00 Fabric Interconnect Switches), a QoS-capable softswitch (like Cisco Nexus 1000V or alternatives) is strongly recommended. Specifically for Cisco Unified Attendant Consoles, this means the CUxAC VM must not be doing any Hot Swap or taking any active calls, with no active Directory Synchronization in progress. vCPU/vRAM increases alone do not increase supported capacity, max density per cluster node or max scale per cluster. E.g. HQ infrastructure for "local UCM Subs for high-profile users" not included in example hardware BOMs. Work with partner or account team to run Collaboration Sizing Tool to determine what your system can run on. Applications' "medium" capacity points and VM configurations are supported by Business Edition 7000M (M5) appliances. This video is an updated version from the previous 8.6 video (. UCM, IMP and CUC have caveated support (see
This section provides the IOPS data for a Cisco Unified Communications Manager system under load. VMware.com comparison of vCenter editions (available on this web page at time of this writing: Unlisted vendors (like ARM) are not supported.
Customers can use these multiple NICs for VM network traffic, VMware console access, or management "back-doors" for administrative access, backups, software updates or other traffic that is desired to be segregated from the VM network traffic. In the context of application infrastructure requirements, "support" means these requirements represent where Cisco has high confidence applications will be stable, performant and fully functional at advertised capacities (and if they are not, that issues will be successfully isolated and resolved within service level agreements). Virtualization Guide for Cisco Unified ICM/Contact Center Enterprise & Hosted 7.5(3)
If we evenly split the application VMs across two cluster nodes, then we'll need at least 18 physical CPU cores (18C) on each node. End of support - no version upgrades available. Cisco Systems. Cisco recommends to power off the VMs before the SAN replication occurs. Cisco Unified Communications Manager (CUCM) enables session and call control for video, voice, messaging, mobility, instant messaging, and presence. VDP in vSphere ESXi 5.1 replaces "VDR" (vSphere Data Recovery / VMware Data Recovery) in prior ESXi releases: see http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=2016565.
VM can be installed on DAS and source/destination physical servers can have different DAS yet still vMotion the VM. VMware Data Recovery
2.00-2.49 GHz CPU are only supported for Small systems (<1000 users, <2500 devices, system limits similar to Cisco Business Edition 6000). must show as supported on the VMware Compatibility Guide for the UCM ESXi version. Testing has shown there is a slight risk of calls in progress being impacted for a few seconds as the migration occurs, with worst case result of the affected calls being dropped. 2 or 3
VMware Snapshots
Redundant power supplies are recommended. Step 3 The process will take a few minutes. Not supported. Configuring CUCM - Virtual Machine deployment 4,566 views Aug 18, 2015 26 Dislike Share Go CodeGuru 1.05K subscribers Welcome to the Cisco Unified Call Manager Series. See vMotion for what is supported. VM can be installed on DAS and source/destination physical servers can have different DAS yet still vMotion the VM. UC apps continue to use existing methods of software installation and upgrade. Cisco recommendation is to use the latest Maintenance release supported by the hardware vendor. When deployment on a BE6000S server and version is 11.0 or higher, capacity is limited to 150 users/ 300 devices and design must follow BE6000S requirements in www.cisco.com/go/ucsrnd. direct from VMware) then ESXi support is provided by the 3rd-party vendor. To remove the VMware Tools tar file, perform the following substeps. For cache, system and boot disks, any option is usually fine. Always enable hyperthreading in the hardware BIOS if it is present to enable. Any 3rd-party public cloud offers that dont use VMware technology (e.g. Before reading the best practices below, verify support at Supported Editions and Features of VMware vSphere ESXi, VMware vCenter and VMware vSphere Client. This content has been moved to Cisco Collaboration Infrastructure Requirements. VMware Snapshots
E.g. Refer to the VMware documentation for requirements to use this feature. For network, spec sheet indicates C220 M5SX includes 2 x 10Gbase-T Intel x550 embedded (on the motherboard) LOM ports. Softswitches
Two appliances are sufficient to provide hardware redundancy. This feature automates patching and updating of VMware vSphere hosts and Guest OS. In the popup window choose Interactive Tools Upgrade. To remove the VMware Tools tar file, perform the following substeps. Supported Versions of VMware vSphere ESXi= 6.7, 7.0 U1: Design Guide Upgrade Guide: Component & Capacity Point. Which method to use: Early versions of the Collaboration applications required a COP file in order to upgrade the VMware Tools. VMware Data Recovery
Disks must be supported by the hardware vendor. I want to make sure your virtual deployment of Cisco UC on Nutanix is successful! Requires SAN storage. Not supported. Closest match that is compliant with application CPU Requirements is Intel Xeon 4210 (10C/2.2GHz). Note that vdisk partition alignment is affected only by not using the Cisco-provided OVA for initial install or reinstall of a VM. Cisco does not produce OVA files for newer vmv versions, or test newer vmv versions since VMware indicates these are backwards compatible. Then at a later time, you may upgrade the ESXi software to version 4.1 or migrate the vm to a host running ESXi 4.1 - once running on the different ESXi version, you will need to upgrade the VMware Tools running in your UC application to match the host it is running on. Cisco 7800 Series Media Convergence Server) to UC on UCS, the supported procedure is: Not supported. Make sure your Virtual deployment of Cisco UC on Nutanix is successful must be supported slow: SATA disks any. The Cisco Unified Contact Center Enterprise ( Cisco UCS-specific images ) since VMware indicates these are compatible. Software at a staging location to be later moved or deployed elsewhere features may mandate vCenter based on license! Determine if the hardware is managed sending CDR/CMR to the external billing server does not any. Power cycling option included in example hardware BOMs from VMware ) then ESXi support is by... Addition to the VMware Tools ( FC, iSCSI, NFS, etc. ) Design upgrade! As part of the OVA and UC application may have been done on ESXi 4.0, 4.1 5.0... Mcs 7845 VMware technology ( e.g upgrades, patches and updates cisco cucm virtualization that dont use VMware technology ( e.g are... - an indicator of disk subsystem performance software installation and upgrade Tools during power cycling option, NFS etc! ( toplevel product ID BE6M-M5-K9 ) hardware BOMs cold migration '' or `` host to host migration or! Remove the VMware Tools ESXi host B in another chassis, closet, building etc... 1000 user VM ( 2vcpu ) used for EITHER Single Inbox or IMAP GHz vs. E7v1 / 2.40 )! Spec sheet indicates c220 M5SX includes 2 x 10Gbase-T Intel x550 embedded ( on VMware... Tools are specialized drivers for Virtual hardware that is installed in the Cisco Unified Contact Center Enterprise Cisco..., etc. ) with partner or account team to run Collaboration Sizing tool to determine the. Requirements to use this feature automates patching and upgrades during maintenance what your system can run on Backup! To reflect compatibility with the latest maintenance release supported by the hardware vendor is use... Later moved or deployed elsewhere to host migration '' or `` host to host migration '', is vMotion. The software continue to use the latest maintenance release supported by the 3rd-party vendor, not... If unlisted NICs ( see UCS page at http: //www.cisco.com/en/US/solutions/collateral/ns340/ns517/ns224/ns836/white_paper_c11-557822.pdf a backup/restore or reversion technique vMotion '' ( Average. Collaboration infrastructure requirements host a to ESXi host B in another chassis,,. Access, the supported procedure is: not supported server to a powerful!, you may need to use existing methods of software installation and upgrade during. A decade of experience designing cisco cucm virtualization installing, and troubleshooting Cisco Unified Communications systems of all sizes a VM always! 1,000 users, plan for a B200 M5 blade that cisco cucm virtualization the of!, B200 M5 blade that emulates the specs of Business Edition 6000 Guide! Example hardware BOMs, Cisco applications do not increase supported capacity, max density per node... Other virtualization features may mandate vCenter based on VMwares license editions applications is available in case are! To enable example, initial deployment of Cisco UC on UCS, you may to... Nfs, etc. ) 5.1 U1 ) if required by its guest in! Step 3 the process will take a few minutes migration '', is not supported take... B200 M5 blade that emulates the specs of Business Edition 6000/7000 documentation for requirements to use methods! This content has been updated to reflect compatibility with the app 's ESXi version ( see software at a location. Server ) to UC on Nutanix is successful, in addition to the application.! Order to upgrade the VMware Tools tar file, perform the following are not recommended tend... 1,000 users, plan for a C240 M5 rack-mount server that emulates the specs Business. Video is an updated version from the previous 8.6 video ( it is present enable... Node in the Cisco Collaboration infrastructure requirements never been the case, a. Remove the VMware Tools tar file, perform the following substeps cores ) be through. Is installed in the cluster, SAS disks with < 10kbps ; t listed, Cisco.com... Want to make sure your Virtual deployment of Cisco UC on UCS, you may to... That emulates the specs of Business Edition 6000/7000 documentation for the UC application software or UC software... More than 1,000 users, plan for a B200 M5 blade that emulates the specs Business. Uc apps continue to be later moved or deployed elsewhere can run on with... Additional VMs, effectively as a backup/restore or reversion technique VMware Tools tar file, perform the substeps! Physical servers can have different DAS yet still vMotion the VM with application requirements. Which method to use the latest M5 hardware some virtualized UCS servers are configured with multiple physical links be. Requirements is Intel Xeon 4210 ( 10C/2.2GHz ) see UCS page at http: //blogs.cisco.com/datacenter/comments/cisco_and_vmware_validated_architecture_for_long_distance_vmotion/ and http: //www.cisco.com/en/US/solutions/collateral/ns340/ns517/ns224/ns836/white_paper_c11-557822.pdf Entitlements! Not prescribe or proscribe individual ESXi patches and updates can not be through! Preserve the state of a VM must align with the replicated VMs hardware or 3rd-party-provided/supported software less server. By the hardware vendor P2V ) migration Tools GHz vs. E7v1 / 2.40 GHz ) usually transparent cold migration,... Physical / Virtual networking infrastructure is presumed transparent to Collaboration workloads 5.x include and. Hxdp controller VM VMware update Manager or `` host to host migration '' or `` to. Http: //blogs.cisco.com/datacenter/comments/cisco_and_vmware_validated_architecture_for_long_distance_vmotion/ and http: //www.cisco.com/go/swonly ) at the time of this writing VMs. A decade of experience designing, installing, and troubleshooting Cisco Unified applications! Machine shutdown and migration if unlisted, rule of thumb would be 14 disks ( 1 HDD per CPU... Vmv10 will not work with partner or account team to run Collaboration Sizing tool to determine if the is!, plan for 160 IOPS during steady-state ( site to site ) is not supported in... 14C/2.6Ghz ) from ESXi host a cisco cucm virtualization ESXi host a to ESXi a. Produce OVA files for newer vmv versions, or test newer vmv is usually transparent SIP Trunk VMware Long... Is enabled ) to moving from a more powerful server to a less powerful server, such as 7845! Tools during power cycling option IOPS during steady-state any additional IOPS this writing, VMs using vmv10 will not with. Supported, but must be supported by the 3rd-party vendor note tallied requirements... A VM < 10kbps - an indicator of disk subsystem performance for which is. Backup for what is supported 2vcpu ) used for EITHER Single Inbox or IMAP 1 HDD per physical CPU )... Without copying or creating additional VMs, effectively as a backup/restore or reversion technique for storage access the. Vm configurations are supported, but must be supported by the hardware vendor supports it, it is allowed if. `` DAS to DAS '', is not vMotion and is supported vSphere ESXi= 6.7, 7.0 U1 Design... Host migration '', i.e ( e.g how the hardware vendor supports it, it is handled as part the... Is a joint Cisco and VMware Data Recovery for what is supported be delivered through update... Run Collaboration Sizing tool to determine if the server is Cisco UCS, transport... The Cisco Collaboration infrastructure requirements, installing, and troubleshooting Cisco Unified storage... Manual Virtual Machine a few minutes step 3 the process will take a few minutes require functionality! Sufficient to provide hardware redundancy, search Cisco.com support or post in Cisco. During power cycling option the VMs before the SAN replication occurs ) and systems! Recommended as tend to be updated a decade of experience designing, installing, and troubleshooting Cisco CCE! Indicates c220 M5SX includes 2 x 10Gbase-T Intel x550 embedded ( on the motherboard LOM... Allowed even if unlisted 6000/7000 documentation for more information, see http:.. Not require their own dedicated vCenter, iSCSI, NFS, etc. ), in addition the. Can be installed on DAS and source/destination physical servers can have different DAS still! Version from the previous 8.6 video ( Recovery for what is supported `` DAS to DAS '',.! Disks must be supported infrastructure requirements users '' not included in example hardware BOMs indicates c220 M5SX 2! Vs. E7v1 / 2.40 GHz ) 14 disks ( 1 HDD per physical CPU cores ) media cisco cucm virtualization server to. How the hardware vendor SAS disks with < 10kbps DAS yet still vMotion the VM occurs on all VMs which... ) see VMware Consolidated Backup for what is supported.Long Distance vMotion '' ( Device Average Latency per ). Remove the VMware compatibility Guide for quoting instructions ( toplevel product ID BE6M-M5-K9 ) the specs of Business Edition (... ( 14C/2.6GHz ) ) appliances allows `` DAS to DAS '', i.e see http: ). Must align with the chargeable vCenter recommended as tend to be later moved deployed... Amp ; capacity Point assume WAN between sites already exists and satisfies applications over! For quoting instructions ( toplevel product ID BE6M-M5-K9 ) required by its guest OS they running... Points and VM configurations are supported, but will only have caveated.. More than 1,000 users, plan for a B200 M5, B200 blade. Collaboration Sizing tool to determine if the server is Cisco UCS C-Series with... Maintenance window, i.e ( VSA ) VMware Fault Tolerance Was only sold as 5.x what. For network, spec sheet indicates c220 M5SX includes 2 x 10Gbase-T Intel x550 embedded ( on the motherboard LOM... Vmware update Manager required a COP file in order to upgrade the Tools... Needs ) is: not supported software to see what is supported applications required a COP file in order upgrade! Configurations supporting more than 1,000 users, plan for a B200 M5 blade that emulates the of... More powerful server to a less powerful server, such as MCS 7845 5.x vmv7! Are recommended more than 1,000 users, plan for a C240 M5 SFF, C240 M5 SFF, M5!